Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал:
http://repository.pdmu.edu.ua/handle/123456789/13529
Повний запис метаданих
Поле DC | Значення | Мова |
---|---|---|
dc.contributor.author | Brailko, N. M. | - |
dc.contributor.author | Tkachenko, I. M. | - |
dc.contributor.author | Kovalenko, V. V. | - |
dc.contributor.author | Nazarenko, Z. Y. | - |
dc.contributor.author | Lemeshko, A. V. | - |
dc.contributor.author | Zelinska, A. B. | - |
dc.contributor.author | Браїлко, Наталія Миколаївна | - |
dc.contributor.author | Ткаченко, Ірина Михайлівна | - |
dc.contributor.author | Коваленко, Віктор Вікторович | - |
dc.contributor.author | Назаренко, Зоряна Юріївна | - |
dc.contributor.author | Лемешко, Анна Валентинівна | - |
dc.date.accessioned | 2020-09-08T08:01:56Z | - |
dc.date.available | 2020-09-08T08:01:56Z | - |
dc.date.issued | 2020-08 | - |
dc.identifier.citation | Laboratory methods of research of adhesive systems / N. M. Brailko, I. M. Tkachenko, V. V Kovalenko [et al.] // Wiadomosci Lekarskie. – 2020. – T. 73, Issue 8. – P. 1726–1730. | uk_UA |
dc.identifier.issn | 0043-5147 | - |
dc.identifier.uri | http://repository.pdmu.edu.ua/handle/123456789/13529 | - |
dc.description.abstract | The aim of our research was to determine the effectiveness of the sealing property of adhesive systems V and VII generations by studying the depth of curing, water absorption and water solubility of their samples. Materials and methods:The study was performed according to ISO / TS 11405: 2015 at the Central Factory Laboratory of JSC “CTOMA”, Kharkiv, Ukraine, Certificate of Attestation No. 100-062 / 2015 dated 03/04/2015. For the study we used specially prepared laboratory samples which were made in the form of plates from adhesive system “DC Adhesive NF” (Dental Central) of V generation “Single bond Universal” (3M ESPE) of VII generation. А monitor and analyze the results obtained used micrometer MK-25, №4694, №03 / 5321 from 08/18/17; caliper SC-1, No. 267447, No. 03/5322 from 08/18/17; scales AP 210, №112144137, №87027 / 9 from 24.11.2017 Results: According to the results of the investigation the following results were obtained: 1) the average curing depth of V and VII generation of adhesive systems was 4.08mm and 3.51mm respectively at the rate of 2mm; 2) average water absorption: 45.97 µg/mm3 and 30.89 µg/mm3 for V and VII generations respectively; 3) the average water solubility was 6.94 µg / mm3 and 4.17 µg / mm3, respectively. Conclusions: According to the results of our laboratory studies, it can be concluded that adhesive systems of V and VII generations can be used for restoration of lesions of tooth hard tissued. Along with this, it can be recommended to use V generation adhesives in closed defects where direct polymerization should be performed and oral fluid access is minimal. Adhesive sysyems of VII generation can be recommended in such cases as: opened restorations, pregingival areas of teeth, cases where a permanent contact of restorations with oral fluid be found along with the cases of autonomic application of adhesive system. | uk_UA |
dc.language.iso | en | uk_UA |
dc.publisher | Aluna Publishing | uk_UA |
dc.subject | adhesive system | uk_UA |
dc.subject | depth of curing | uk_UA |
dc.subject | water absorbtion | uk_UA |
dc.subject | water solubility | uk_UA |
dc.title | Laboratory methods of research of adhesive systems | uk_UA |
dc.type | Article | uk_UA |
dc.identifier.doi | 10.36740/WLek202008126 | - |
Розташовується у зібраннях: | Наукові праці. Кафедра пропедевтики терапевтичної стоматології |
Файли цього матеріалу:
Файл | Опис | Розмір | Формат | |
---|---|---|---|---|
brailko.pdf | 823,19 kB | Adobe PDF | Переглянути/Відкрити |
Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.