Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repository.pdmu.edu.ua/handle/123456789/21881
Назва: Comparative characteristics of the properties of dental implants depending on the design, shape and surface in the experiment
Автори: Kaplun, Dmytro
Avetikov, David
Lokes, Kateryna
Ivanytska, Olena
Каплун, Дмитро Володимирович
Аветіков, Давид Соломонович
Локес, Катерина Петрівна
Іваницька, Олена Сергіївна
Дата публікації: 2023
Видавець: Ausra, Kaunas, Lithuania
Бібліографічний опис: Comparative characteristics of the properties of dental implants depending on the design, shape and surface in the experiment / D. Kaplun, D. Avetikov, K. Lokes, O. Ivanytska // Stomatologija. Baltic Dental and Maxillofacial Journal. – 2023. – Vol. 25, № 1. – P. 21–25.
Короткий огляд (реферат): The aim of the study. Compare the properties of different dental implants depending on the design, shape and surface area in the experiment. Materials and methods. Dental implants with similar sizes (5.5×10 mm) were selected: Vitaplant VPKS, Mega Gen AnyRidge and Alpha Dent Superior Active. The calculation of the total area of the implants was performed and the implants were immersed in a ferromagnetic substance. Results and discussion. The small number of turns and their small length of the Vitaplant implant cannot create a large surface area (this size of the implant has an area of 174.7 mm2 ). On the thin, slightly conical body of the MegaGen implant (North Korea), the developer placed 10 turns of thread with wide blades. Due to the data design features, this implant has the largest surface area (276.5 mm2 ), which is an advantage in implant integration. The same number of turns (10) and a very similar frequency bring Alpha Dent implants (Germany) closer to the implant described above, but the design implements an innovative anti-rotation system. This implant size has a total surface area of 210.5 mm2 . Conclusions. The implant Vitaplant VPKS is inferior in effi ciency of the geometry of the implant Mega Gen AnyRidge by 24%, and the implant Alpha Dent Superior Active in turn ahead of the effi ciency of the representative of the Korean company by 8.9%. The shape of the geometry of the implant affects the effectiveness of counteracting the masticatory load more than its surface area.
Ключові слова: shape of dental implant
efficiency of the geometry
URI: http://repository.pdmu.edu.ua/handle/123456789/21881
Розташовується у зібраннях:Наукові праці. Кафедра хірургічної стоматології та щелепно-лицевої хірургії