Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repository.pdmu.edu.ua/handle/123456789/8865
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorЯрковий, Віталій Васильович-
dc.contributor.authorКороль, Михайло Дмитрович-
dc.contributor.authorКіндій, Дмитро Данилович-
dc.contributor.authorОджубейська, Ольга Дмитрівна-
dc.contributor.authorМалюченко, Микола Миколайович-
dc.contributor.authorЯрковой, Виталий Васильевич-
dc.contributor.authorКороль, Михаил Дмитриевич-
dc.contributor.authorКиндий, Дмитрий Данилович-
dc.contributor.authorОджубейская, Ольга Дмитриевна-
dc.contributor.authorМалюченко, Николай Николаевич-
dc.contributor.authorIarkovyj, V. V.-
dc.contributor.authorKorol, M. D.-
dc.contributor.authorKindiy, D. D.-
dc.contributor.authorOdzhubeiska, O. D.-
dc.contributor.authorMaliuchenko, M. M.-
dc.date.accessioned2018-11-06T02:05:00Z-
dc.date.available2018-11-06T02:05:00Z-
dc.date.issued2018-
dc.identifier.citationПорівняльна характеристика фізико-механічних властивостей кальційтермічного цирконію та титану / В. В. Ярковий, М. Д. Король, Д. Д. Кіндій [та ін.] // Вісник проблем біології і медицини. – 2018. – Вип. 1, т. 2 (143). – С. 295–298. DOI 10.29254/2077-4214-2018-1-1-2-143-295-298.uk_UA
dc.identifier.issn2077-4214-
dc.identifier.otherDOI 10.29254/2077-4214-2018-1-1-2-143-295-298.-
dc.identifier.otherУДК 616–77–089.843:546.831:546.82–042.2-
dc.identifier.urihttp://repository.pdmu.edu.ua/handle/123456789/8865-
dc.description.abstractРезюме. В роботі представлені результати фізико-механічних досліджень кальційтермічного цирконію і титану, які застосовуються для виготовлення стоматологічних імплантатів. Для дослідження фізико-механічних властивостей сплавів титану і цирконію виготовляли зразки, які у вигляді циліндра мали діаметр 3 мм і висоту 10 мм. Кількість зразків була по 5 штук з цирконію і титану. Із промислових прутків обох матеріалів виготовлялися циліндричні зразки діаметром 3 мм і довжиною 10 мм, які деформувалися стиском уздовж осі зі швидкістю 0,1 мм/хв на деформаційній машині МРК-1 з реєстрацією діаграми деформації на самописці КСП-4. Мікротвердість зразків обох металів у вигляді пластин розміром 6х6х2 мм3, одна з поверхонь яких була відшліфована і відполірована алмазною пастою до дзеркального вигляду вивчалася на мікротвердометрі ПМТ-3 при двох навантаженнях на індектор – 0,1Н і 0,2Н. На підставі проведених досліджень доведено, що за деякими фізико-механічними характеристиками кальційтермічний цирконій перевищує титан ВТ-1-00, а це дозволяє рекомендувати його для використання в стоматології з метою виготовлення дентальних імплантатів.; В работе представлены результаты физико-механических исследований кальцийтермического циркония и титана, которые применяются для изготовления стоматологических имплантатов. Для исследования физико-механических свойств сплавов титана и циркония изготовляли образцы, которые в виде цилиндра имели диаметр 3 мм и высота 10 мм, которые деформировались сжиманием вдоль оси со скоростью 0,1 мм/хв на деформационной машине МРК- 1 с регистрацией диаграммы деформации на самописке КСП- 4. Количество образцов были по 5 штук из циркония и титана. Микротвердость образцов обоих металлов в виде пластин размером 6х6х2 мм3 , одна из поверхностей которых была отшлифована и отполирована алмазной пастой до зеркального вида и изучалась на микротвердометре ПМТ- 3 при двух нагрузках на индектор - 0,1Н и 0,2Н. На основании проведенных исследований доказано, что по некоторым физико-механическим характеристикам кальцийтермический цирконий превышает титан ВТ- 1-00, а это позволяет рекомендовать его для использования в стоматологии с целью изготовления дентальных имплантатов.;The results of physico-mechanical studies of calciothermic zirconium and titanium used for dental implants manufacturing are presented in the paper. The physical and mechanical properties of titanium and zirconium alloys were studied on samples made in the form of cylinder with 3 mm diameter and 10 mm of height. The number of studied samples amounted to 5 pieces of both zirconium and titanium. Cylindric samples with 3 mm diameter and 10 mm of length were made from industrial rods of both materials, which were deformed by compression along the axis at a speed 0.1 mm/min using MRK-1 deformation device with strain diagram registration applying self-recording device KSP-4. The samples of both metals were presented in the form of plates with the size 6x6x2 mm3; one surface of each was ground and polished with diamond paste to a mirror-like. Their microhardness was studied using PMT-3 microhardness tester at two loads − 0.1N and 0.2N. The average value of the yield point of zirconium was about 16% greater than that of titanium. The stress relaxation was also studied in the framework of compression research. The deformation device was stopped directly after reaching the yield point and the stress relaxation curve was recorded. The so-called activation volume V could be determined in the framework of the logarithmic equation of stress relaxation by the analysis of its temporary dependence. The size of the activation volume was found to be the same for titanium BT-1-00 and calciothermic zirconium, 0.83 • 10-27 m3 and 1.1 • 10-27 m3 , respectively. The difference between the presented sizes could be considered insignificant, and the size order itself indicated the sufficiently high density of dislocation defects in these materials. The microhardness of titanium BT-1-00 was significantly lower, than that of calciothermic zirconium at the load of 0.1 N in all series of studied samples, which was 162.6 MPa and 202.6 MPa, respectively. At the load of 0.2 N the microhardness indices of the alloys were lower, than at the load of 0.1 N and amounted to 157.8 MPa in titanium BT-1-00 and 186.8 MPa in zirconium. When comparing the average values, the difference between titanium BT-1-00 and calciothermic zirconium microhardness amounted to 37 MPa. This fact confirmed that calciothermic zirconium microhardness was significantly higher than that of titanium BT-1-00. On the basis of the conducted studies, it has been proved that calciothermic zirconium was better than titanium BT-1-00 for some physico-mechanical characteristics, which allows us to recommend it for dental implants manufacturing.uk_UA
dc.language.isoukuk_UA
dc.publisherВищий державний навчальний заклад України «Українська медична стоматологічна академія»uk_UA
dc.subjectімплантатиuk_UA
dc.subjectкальційтермічний цирконійuk_UA
dc.subjectтитанuk_UA
dc.subjectмікротвердістьuk_UA
dc.subjectмежа текучості металівuk_UA
dc.subjectимплантатыuk_UA
dc.subjectкальцийтермический цирконийuk_UA
dc.subjectтитанuk_UA
dc.subjectмикротвердостьuk_UA
dc.subjectпредел текучести металловuk_UA
dc.subjectimplantsuk_UA
dc.subjectcalciothermic zirconiumuk_UA
dc.subjecttitaniumuk_UA
dc.subjectmicrohardnessuk_UA
dc.subjectyield strengthuk_UA
dc.titleПорівняльна характеристика фізико-механічних властивостей кальційтермічного цирконію та титануuk_UA
dc.title.alternativeСравнительная характеристика физико-механических свойств кальцийтермического циркония и титанаuk_UA
dc.title.alternativeComparative characteristics of physico-mechanical properties of calciothermic zirconium and titaniumuk_UA
dc.typeArticleuk_UA
Розташовується у зібраннях:Наукові праці. Кафедра пропедевтики ортопедичної стоматології
Вісник проблем біології і медицини, Випуск 1, Том 2 (143)

Файли цього матеріалу:
Файл Опис РозмірФормат 
Comparative_characteristics_of_physico-mechanical_properties.pdf2,23 MBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.