Перегляд за Автор "Yanishen, I. V."
Зараз показуємо 1 - 5 з 5
Результатів на сторінці
Налаштування сортування
Документ Assessment of microecology of the oral cavity during the period of adaptation to dual-layer structures of dentures with a obturating part(Українська медична стоматологічна академія, 2019) Yanishen, I. V.; Fedotova, O. L.; Pogorila, A. V.; Sokhan, M. V.; Yanishena, Y. I.Документ Wear resistance of dental materials which are used for anterior teeth restorations(Aluna Publishing, 2020-08) Yanishen, I. V.; Tkachenko, I. M.; Skrypnikov, P. M.; Hasiuk, P. A.; Янішен, Ігор Володимирович; Ткаченко, Ірина Михайлівна; Скрипников, Петро Миколайович; Гасюк, Петро АнатолійовичThe aim of this study was to compare the wear resistance of such restorative materials as composite resin, feldspathic ceramic, leucite glass ceramic with intact enamel and to draw an analogy with some similar researches. Materials and methods: In this research 20 extracted human teeth (maxillary incisors) without fillings and carious cavities were used as samples. All samples were disinfected and stored in saline in order to prevent dehydration. Teeth roots were cut off for the measure of fixation on an organic glass plate using chemically polymerizable resin. Ifnecessary, the teeth were also cut on their lateral sides in order to give them equal size. The samples were placed in a frame-holder, located on the lever of the machine MI-2, which determines abrasion resistance under slipping. Results:The research has revealed that the average wear resistance of natural teeth was 122,67±4.9J/mm3 (Tab 1). The archived result overcomes dental composite resin twice more (62.8±1.21 J/mm3), feldspathic ceramic 6.5 times more (16.32±1.2 J/mm3) andleucite ceramic over the half (73.79±3.12 J/mm3) Conclusion: Thus, according to this performed research and the analysis of the relative literature sources it can be stated that dental composite resin and leucite ceramics may be proposed as the materials of choice for anterior restoration of teeth. They have shown the good wear resistance and tolerance to antagonizing natural teeth.Документ Вплив різних методів дезінфекції на розмірну точність відбиткових А-силіконових матеріалів(Полтавський державний медичний університет, 2018) Янішен, І. В.; Герман, С. А.; Ярина, І. М.; Янишен, И. В.; Герман, С. А.; Ярина, И. Н.; Yanishen, I. V.; German, S. A.; Yarina, I. M.Метою дослідження було провести порівняльну оцінку впливу експозиції дезінфікуючих засобів на розмірну точність відбиткових А-силіконових матеріалів в порівнянні з металевою майстер моделлю. Отримані дані свідчать про те що, в цілому методи дезінфекції А-силіконових відбиткових матеріалів не значно впливали на відносну розмірну точність гіпсових моделей, в межах 0,03-0,066%, що відрізняється від контрольної групи з відсутністю етапу дезінфекції відбитків менш ніж на 0,04%. Дослідження показало, що дезінфекція не робить істотного впливу на розміри А-силіконового відбиткових матеріалів і отриманих по ним гіпсовим моделям. Перевищення тривалості дезінфекції впливає на якість відбитків і точність виготовлених незнімних конструкцій протезів.Документ Оцінка якості незнімних конструкцій зубних протезів(Українська медична стоматологічна академія, 2016) Янішен, Ігор Володимирович; Yanishen, I. V.На основі аналізу безпосередніх, віддалених результатів і клініко-технологічної оцінки ускладнень опрацьовано та впроваджено методику порівняльного аналізу якості пластмасових і комбінованих штучних коронок і мостоподібних протезів за комплексом показників. Доведено, що якість штучних коронок визначається тривалістю клінічної експлуатації. Доведено, що якість мостоподібних протезів визначається тривалістю клінічної експлуатації конструкції, їх різновидом та не залежить від однорідності конструкційного матеріалу; На основе анализа непосредственных и отдалённых результатов, а также клинико-технологической оценки осложнений разработано и внедрено методику сравнительного анализа качества пластмассовых и комбинированных исскуственных коронок и мостовидных протезов по комплексу показателей. Доказано, что качество исскуственных коронок определяется сроками их клинической эксплуатации. Доказано, что качество мостовидных протезов определяется не только сроками эксплуатации, но и их типом и не зависит от однородности использованных конструкционных материалов; Abstract. The purpose of the research was aimed at comparative analysis of quality of fixed dentures at the stages of its clinical durability. Materials and Methods. The results of expert evaluation, performed in compliance with f.043/о in 10 medioprophilactic institutions comprised the following mode of dataware: the total amount of studied fixed dentures was 35950 pieces; the total number of prosthodontist was 75 individuals, dental mechanics were 103 individuals. The comparative quality assessment of 20329 artificial crowns (13304 plastic crowns and 7025 combined crowns according to Byelkin, Borodyuk, Ahmetov), 15621 bridge dentures (9789 plastic dentures and 5832 combined dentures) has been made at the stages of clinical durability of prosthetic appliances. In comparative quality assessment of fixed dentures the following indicators have been used: index of clinicaltechnological quality (ІТЯ – total number of signs of decrease in quality of prosthetic appliance and total number of such appliances ratio) and efficiency index (ЯП, % - density of prosthetic appliances of satisfactory quality). Results and Discussion. Time periods and signs of decrease in quality of plastic and combined artificial crowns have been studied. The study showed that quality of artificial crowns is defined by the length of dentures’ clinical durability and their type (plastic/combined). So, at the early stage of clinical durability artificial crowns are characterized by the higher level of quality, than combined ones (ЯП: (96,8±0,8)% and (92,1±1,6)%, respectively; р<0,05), which depends on overall rate of specific signs of decrease in quality of the appliances ((3,2±0,8)% for plastic crowns; (12,0±2,5)% for combined crowns; р<0,01) and ratio of prosthetic appliances with the signs of quality decrease (ІТЯ : (1,4±0,1)% for plastic crowns; (1,3±0,1)% for combined crowns; р<0,01). In the remote period of clinical durability plastic crowns are characterized by more apparent decrease in quality level of prosthetic appliance than combined ones (ЯП: (52,9±3,5)% and (39,1±3,7)%, respectively; р<0,05), which occurs, first of all, due to increase of the overall rate of individual signs of decrease in quality of appliance ((47,1±3,5)% for plastic crowns; (77,9±9,6)% for combined crowns; р<0,01); at the same time ІТЯ remains stable. The quality of bridge dentures depends on different reasons and is also defined by the length of clinical durability of the appliance and its type (plastic or combined ones). The decrease in quality of bridge dentures occursьdue to the increase of overall rate of specific signs of decrease in quality of the appliance ((69,1±4,6)% for plastic dentures; (65,2±5,0)% for combined ones; р<0,05); at the same time ІТЯ of comparing appliances does not significantly differ and constitutes on the average 1,4+0,07. Conclusions. The technique of comparative analysis of quality of fixed dentures has been studied and implemented at the stages of clinical durability of plastic and combined artificial crowns and bridge dentures according to the range of indices.It has been proved by evidence, that quality of artificial crowns is defined by the length of clinical durability of the appliance and is significantly higher, than the quality of combined ones at the early stage of their clinical durability; at the same time in the remote period of clinical durability plastic crowns are characterized by higher rates of quality index. It has been proved by evidence that quality of bridge dentures is defined by the length of clinical durability of the appliance, their type, and does not depend on similarity of the constructive material in the early and remote period. Perspectives of further research, devoted to this problem, are connected with grounding of constructive-andcompliant constructive and supplemental dental materials as well as study of quality of life of patients at the stages of clinical durability of fixed dentures.Документ Порівняльна оцінка результатів лабораторного дослідження міцності адгезії А-силіконового матеріалу при виготовленні двошарових конструкцій знімних протезів(Українська медична стоматологічна академія, 2018) Янішен, Ігор Володимирович; Запара, Павло Сергійович; Федотова, О. Л.; Yanishen, I. V.; Zapara, P. S.; Fedotova, О. L.Небезпека шкідливої дії невдало підібраних стоматологічних матеріалів виявляє актуальну потребу використання сучасних підходів у професійній діяльності задля забезпечення необхідної якості конструкцій і їхніх клініко-функціональних властивостей. Мета дослідження – підвищення якості ортопедичного лікування пацієнтів знімними конструкціями з обтуруючою частиною з двошаровими базисами за рахунок наукового обґрунтування добору м’якої підкладки й акрилової пластмаси. Порівняльну оцінку міцності зв’язку проводили спільно зі співробітниками центральної заводської лабораторії АТ «Стома» (Харків, Україна) відповідно до вимог міжнародного стандарту ISO-10139. Результати показали, що найвищий ступінь комплаєнтності має система вітчизняних матеріалів «ПМ-СН»-«Стомаліт». Перспективи подальших досліджень очевидні, а роботу в цьому аспекті можна вважати не тільки потрібною, а й необхідною, оскільки дослідження комплаєнтності матеріалів безсумнівно істотно допоможе лікарю-стоматологу ортопеду визначитися з вибором конструкційного матеріалу при виготовленні двошарових зубних протезів; Опасность вредного воздействия неудачно подобранных стоматологических материалов указывает на необходимость использования современных подходов в профессиональной деятельности для обеспечения необходимого качества конструкций и их клинико-функциональных свойств. Цель исследования - повышение качества ортопедического лечения пациентов съемными конструкциями с обтурирующей частью с двухслойными базисами за счет научного обоснования подбора мягкой подкладки и акриловой пластмассы. Сравнительную оценку прочности связи проводили совместно с сотрудниками центральной заводской лаборатории АО «Стома» (Харьков, Украина) в соответствии с требованиями международного стандарта ISO-10139. Результаты показали, что самую высокую степень комплаентности имеет система отечественных материалов «ПМ-СН» - «Стомалит». Перспективы дальнейших исследований очевидны, а работу в этом аспекте можно считать не только нужной, а и необходимой, так как исследование комплаентности материалов несомненно существенно поможет врачу-стоматологу ортопеду определиться с выбором конструкционного материала при изготовлении зубных протезов;Background. The risk of negative influence of unsuccessful selection of dental materials reveals the urgent need to use modern approaches in professional activity in order to provide the necessary quality of structures and their clinical and functional properties. The purpose of the study is to improve the quality of orthopedic treatment of patients with removable structures with an obturating part with two-layer bases due to the scientific substantiation of the selection of both soft substrates and acrylic plastics. Materials and methods. A comparative assessment of the connection strength was carried out jointly with the employees of the central factory laboratory of JSC "Stoma" (Kharkiv, Ukraine) in accordance with the requirements of the international standard ISO-10139. Research results. A comparative analysis of the study of the adhesion of A-silicon substrate materials to removable denture constructs made of acrylic plastics by various laboratory technologies included the results of a laboratory study of one of the most important physico-mechanical properties - bond strength. Investigation of bond strength (U, kgf / cm2) of material for soft substrates "PM-S" and acrylic polymer "Stomalite" found that its index is (5.3 ± 0.2) kgf / cm2 (Table. 1) and conforms to the regulatory requirements of ISO-10139. However, it was found that the index of the bond strength of the "PM-S" with the plastic "Pallopress" is equal to (5.5 ± 0.3) kgf / cm2, which is significantly (p <0,05) higher than the contact the material is "Villacryl H Plus" - (5.1 ± 0.2) kgf / cm2. The strength of the connection between the "PM-S extra" and the acrylic basis made from "Stomalite" is (6.9 ± 0.2) kgf / cm2, which exceeds the indicative index by 72.5% and is significantly (p <0 , 05) greater than in the combination of "PM-S" extra with "Pallopress" (6.8 ± 0.1) kgf / cm2 and "Villacryl H Plus" (6.7 ± 0.2) kgf / cm2. Polyvinyl siloxane material "PM-SN" is connected with acrylic plastic "Stomalite" with a strength of (9.3 ± 0.2) kgf / cm2. This indicator significantly (2.3 times) exceeds the indicative value (≥4.0 kgf / cm2) according to ISO-10139, which meets the quality requirements, and reliably (p <0.01) exceeds the results of research on the connection strength between "PM-CH" and "Pallopress" and "PM-SN" and "Villacryl H Plus", which are (9.0 ± 0.1) kgf / cm2 and (8.9 ± 0.2) kgf / cm2, respectively, and also meet the ISO requirements for this indicator. The study of the bond strength between the "Ufi Gel P" substrate and the "Stomalit" acrylic base plastics showed one of the best results throughout the study (9.1 ± 0.2) kgf / cm2, yet it is still inferior to the leading position of the "PM-CH"-"Stomalit" by 2.2%. However, in the "Ufi Gel P" bonding comparison group with other plastics, the result of the "Ufi Gel P" - "Stomalit" system was significantly (p <0,05) better than the "Ufi Gel P" - "Pallopress system" - (8.9 ± 0.3) kgf / cm2, which in turn inferior to the complex "Ufi Gel P" - "Villacryl H Plus" (8.8 ± 0.1) kgf / cm2. All of these systems comply with ISO-10139. The strength of the connection between materials "Silagum" and "Stomalite" is (5.9 ± 0.2) kgf / cm2, which corresponds to the normative requirements of ISO-10139 according to this indicator, but reliably (p <0.05) is slightly inferior to the system "Silagum" - "Pallopress" with a value of (6.0 ± 0.3) kgf / cm2, but 2.5% ahead of the connection "Silagum" and "Villacryl H Plus"- (5.8 ± 0.3) kgf / cm2 (p <0.05). Conclusions. A generalized analysis of the results showed that all the studied systems meet the regulatory requirements of ISO-10139. However, the highest step in determining the compliance with the connection strength is the system of domestic materials "PM-SN" - "Stomalite". Prospects for further research are obvious and work in this aspect can be considered not only necessary, but necessary, as conducting studies of compliance of materials will undoubtedly significantly help the dentist's orthopedist to determine the choice of structural material in the manufacture of two-layer dentures.