Comparative assessment of morphometric parameters of structural elements of crypts of the cecum using surgical threads polyglactin-910 and polycaprolactone modified with l- arginine in the experiment

dc.contributor.authorPronina, O. M.
dc.contributor.authorBilash, S. M.
dc.contributor.authorKobeniak, M. M.
dc.contributor.authorOliinichenko, Ya. O.
dc.contributor.authorKoptev, M. M.
dc.contributor.authorPirog-Zakaznikova, A. V.
dc.contributor.authorDonchenko, S. V.
dc.contributor.authorKononov, B. S.
dc.contributor.authorOleksiienko, V. V.
dc.contributor.authorMamai, O. V.
dc.contributor.authorПроніна, Олена Миколаївна
dc.contributor.authorБілаш, Сергій Михайлович
dc.contributor.authorКобеняк, Микола Миколайович
dc.contributor.authorОлійніченко, Ярина Олександрівна
dc.contributor.authorКоптев, Михайло Миколайович
dc.contributor.authorПирог-Заказникова, Ангеліна Валеріївна
dc.contributor.authorДонченко, Світлана Владиславівна
dc.contributor.authorКононов, Богдан Сергійович
dc.contributor.authorОлексієнко, Владислав Віталійович
dc.contributor.authorМамай, Олександр Володимирович
dc.date.accessioned2025-04-09T06:39:23Z
dc.date.available2025-04-09T06:39:23Z
dc.date.issued2025-01-30
dc.description.abstractThe article presents a research study conducted to comparatively examine the effects of synthetic absorbable polyglactin-910 sutures and a novel suture material, polycaprolactone modified with L-arginine (PCL-MA), on the morphometric parameters of the crypts in the mucosa of the cecum under experimental conditions. Surgical interventions were performed on 65 sexually mature outbred domestic rabbits aged 9-10 months and weighing (2.62±0.21) kg, which were divided into three groups: control and two experimental groups (the first one using PG-910 surgical thread and the second one using surgical thread PCL-MA). After the surgical intervention, the condition of the wound and the formed scar were studied on days 3, 7, 14, 21, 30, and 60. The morphometric method was used to analyze quantitative changes in the structural components of crypts in the cecum's perivulnar area in the experiment's dynamics. Statistically, the reliability of these quantitative changes was established. As a result of the study, it was found that when PCL-MA is used for suturing a wound defect, the functioning of the structural components of the crypts in the mucosa of the perivulnar area of the cecum is faster on average by 7 days than when using PG-910.
dc.identifier.citationComparative assessment of morphometric parameters of structural elements of crypts of the cecum using surgical threads polyglactin-910 and polycaprolactone modified with l- arginine in the experiment / O. M. Pronina, S. M. Bilash, M. M. Kobeniak, Ya. O. Oliinichenko, M. M. Koptev, A. V. Pirog-Zakaznikova, S. V. Donchenko, B. S. Kononov, V. V. Oleksiienko, O. V. Mamai // Azerbaijan medical journal = АТJ. – 2025. – № 1. – P. 183–189.
dc.identifier.doi10.34921/amj.2025.1.032
dc.identifier.issn0005-2523
dc.identifier.urihttps://repository.pdmu.edu.ua/handle/123456789/26097
dc.language.isoen
dc.publisherWHO Office in Azerbaijan
dc.subjectintestine
dc.subjectmorphometry
dc.subjectL-arginine
dc.subjectcrypts
dc.subjectmucosa
dc.subjectintestinal wall
dc.subjectsurgical thread
dc.titleComparative assessment of morphometric parameters of structural elements of crypts of the cecum using surgical threads polyglactin-910 and polycaprolactone modified with l- arginine in the experiment
dc.title.alternativeL-argininlə modifikasiya edilmiş poliqlaktin-910-dan və polikaprolaktondan eksperimentlə istifadə zamani kor bağirsağin struktur elementlərinin morfometrik parametrlərinin müqayisəli qiymətləndirilməsi
dc.typeArticle

Файли

Контейнер файлів
Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
Pronina_Comparative_assessment_of_morphometric_parameters.pdf
Розмір:
255.78 KB
Формат:
Adobe Portable Document Format
Ліцензійна угода
Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
license.txt
Розмір:
4.3 KB
Формат:
Item-specific license agreed upon to submission
Опис: